• XRS-160-6.25K-HE
  • • Ratings: 160kVp @ 6.25mA, 1000W
  • • Applications: Irradation


Note: All specifications are subject to change without notice. Please consult the PDF version of this datasheet for the most up-to-date revision.

Specifications

Model No:
XRS-160-6.25K-HE
Load Reg. (kVp)
0.50%
Modality Served
Industrial
Line Reg. (mA)
Applications
Irradation
Load Reg. (mA)
Power Supply
HF Inverter
Ripple
< 1%
X-Ray Tube
Glass
Rise Time (kVp)
<1.0 Sec
Min. Focal Spot
2.5 mm
Set-ability
0.50%
Port Material
Ultem
Temp Stability
0.10%
Input Power
100 - 240 VAC
Operating Temp.
0 - 35° C
Duty Cycle
Continuous
Storage Temp.
0 - 43° C
Cooling
Integrated Heat Exchanger
Size (approx. ")
18.25 x 18.0 x 8.0
kVp Range
40 - 160
Weight (approx.)
125 Lbs.
mA Range
0.1 - 6.25 mA
X-Ray Shielding
Yes
Line Reg.(kVp)
0.50%
Warranty
1 Year, X-Ray Tube I year Prorated

Custom Configurations Available.

* nominal spot sizes per IEC336, JISZ47045, NEMA XR5

Optional Control Units: Reference Individual Brochures for Specifications

Digital Interface: Model DI-RS232

Human Machine Interface: Model PI-3.8A

UL 60601-1 on Models: SB-50-1K-BW, SB-60-50, SB-80-250, SB-80-500 & SB-80-1K